Please Note: You are viewing the unstyled version of POLARIS Laboratories. Either your browser does not support CSS (Cascading Style Sheets) or it is disabled. As a result, much of this website will not look the way it was intended, although all of its contents will be accessible to you. For more information, visit our Browser Support page.

Skip to Primary Site Navigation, Secondary Site Navigation, Content, Company Address


Home > Technical Bulletins > ICP Could Be Telling Only Half the Story

ICP Could Be Telling Only Half the Story

If you depend solely on Elemental Analysis by ICP to detect wear metal concentrations, you may not always know when a catastrophic failure is in progress.

Elemental Analysis by ICP (inductively coupled plasma) detects up to 24 metals that can be present in used oil due to wear, contamination or additives. But, only particles measuring less than 10µ in size are seen. To determine if larger wear is occurring, Particle Quantifying or Particle Counting should be used in conjunction with ICP.

Particle Quantifying — (ferrous density) exposes a lubricant to a magnetic field. The presence of any ferrous metals causes a distortion in the field, which is represented as the PQ Index, an arbitrary unit of measurement that correlates well with DR ferro large. If the PQ Index is smaller than iron ppm by ICP, it's unlikely there are any particles larger than 5 microns present. But if the PQ Index increases dramatically while the ICPs iron ppm remains consistent or goes down, larger ferrous particles are being generated and further testing or diagnostics are recommended.

Particle Count — is the measurement of all particles that have accumulated within a system, including those metallic and non-metallic, fibers, dirt, water, bacteria and any other kind of debris. However, it is most useful in deterring fluid cleanliness in filtered systems such as hydraulics, turbines, compressors, auto/power shift transmissions, recirculation systems and filtered gear systems with a fluid viscosity of less than ISO 320.

When large ferrous wear is confirmed, microscopic analysis, such as Analytical Ferrography or Micropatch should be used to qualify the type of wear occurring and identify its source.

Click here for more information on Analytical Ferrography and Micropatch testing.

Print this Technical Bulletin (PDF - 96K)


Top

News

POLARIS Laboratories™ to provide fluid analysis for AES Defence Early Failure Detection Centre

POLARIS Laboratories™, an innovative leader in fluid analysis services in North America, announced today their partnership with UK-based AES Defence who provides oil analysis services for more than 1,500 British military vehicles.

Read More

Sign Up for eNewsletters


Training

  • Salt Lake City
    Practicing Oil Analysis
    March 30-31, 2010

  • Houston
    Practicing Oil Analysis
    June 22-23, 2010

  • Indianapolis
    Cooling Systems Maintenance
    July 20, 2010

View complete schedule and registration information


Tradeshows & Conferences

  • AEMP
    Dallas, TX
    March 14-16, 2010

  • Truck World
    Toronto, ON
    April 15-17, 2010

View all tradeshows