Primary Navigation
How Take An Oil Sample
Using A Vacuum Pump
The Vacuum Pump is used to extract samples from a dipstick or non-pressurized system. When extracting the sample, it is important to use a new piece of tubing in order to avoid sample contamination. It is also important to have an appropriate container and follow all the directions thoroughly to ensure that the oil sample is representative of all the oil in the machine.
Step 1 — Carefully unpack the POLARIS Sample Kit, place material on a clean surface and fill out sample jar label. Measure tube to the length of reservoir tank or dipstick, add 6 inches to the measurement and place mark on the tube.
Step 2 — Insert the tube through the head of the vacuum pump and tighten lock ring. The tube should extend about 1 inch beyond the base of the vacuum pump head.
Step 3 — Screw in the white sample jar to the bottom of the vacuum pump and tighten securely. Place tube into the oil, retaining tube up to the mark on the tube.
Step 4 — Push and pull the vacuum pump plunger a few times to start the suction. Continue pumping until sample jar is 3/4 full. Hold the pump upright in order to avoid contamination.
Step 5 — Unscrew the sample jar from the vacuum pump and place the lid back on the sample jar and tighten securely. Drain remaining fluid out of tube into tank and remove tube from fill port. Unscrew locking ring on vacuum pump, remove and properly dispose used tube. Place the sample jar label on sample jar and the appropriate return-mailing label on black return mailer. Send the sample to the lab immediately.
Using A KST Series Probe Sampling Valve
The KST Series Probe Sampling Valve is a needle valve that is installed on a pressurized system. The valve should be installed on a pressurized line with a minimum of 4 psi - maximum of 1000 psi. It requires the use of the KST Series Cap to insert into the valve to retrieve sample. It consists of a jar cap, 4 inch tube with a needle and a vent opening to allow flow.
POLARIS Laboratories, LLC has developed oil analysis kits in order to make oil analysis convenient, easy and simple. These kits include pump, tubing, jars and pre-addressed mailers.
Step 1 — Make sure the unit is at our close to normal operating temperature. Take the KST Series cap and needle assembly up to the sample valve. Hold a separate waste container under the KST Series cap and insert the needle probe into the valve. Flush at least 3 times the fluid into the container. Remove the needle probe to stop the flow and set the separate container in a safe place.
Step 2 — Remove the cap from the sample container. Place the KST Series cap onto the sample container and secure it firmly. Take the sample container with the KST Series cap and insert the needle probe into the valve. Fill the sample container to approximately 3/4 full.
Step 3 — Remove the needle probe to stop the flow. Place the cap onto the sample container securing it firmly. Tighten the protective cap back onto the valve. Wipe the valve with a clean rag to remove any excess fluid. Discard the KST Series cab assembly in a safe manner.
Step 4 — Place the sample jar label on sample jar and the appropriate return-mailing label on black return mailer. Send the sample to the lab immediately.
Using A KP Series Pushbutton Sampling Valve
The KP Series is a push button sampling valve that is installed on a pressurized system. The valve should be installed on a pressurized line with a minimum of 4 psi - maximum of 100 psi.
Step 1 — Make sure the unit is at or close to normal operating temperature. Remove the protective cap from the valve. Place a separate waste under the valve opening. Press the KP Series button and flush at least 3 times the fluid into the separate container. Dispose the waste oil properly.
Step 2 — Remove the lid from the sample container. Place the sample container under the valve opening. Press the KP Series button to dispense fluid into the sample container filling it to approximately 3/4 full.
Step 3 — Release the KP Series button to close the valve. Place the protective cap back onto the valve securing it firmly. Screw the cap onto the sample container closing it tightly.
Step 4 — Place the sample jar label on sample jar and the appropriate return-mailing label on black return mailer. Send the sample to the lab immediately.
Print this Technical Bulletin (PDF - 109K)
Quick Links
News
New Fuel Test Packages Will Reduce Fleet Expenses and Downtime
POLARIS has developed an extensive range of fuel troubleshooting test packages that can confirm the quality of bulk deliveries and resolve what might be causing costly repairs and fleet downtime. Fleet managers spend more money on fuel than any other operating expense, so this is an area of great importance.
POLARIS Named Fluid Analysis Provider for Industry's Largest International Oil Distributor Group
The Association of Independent Oil Distributors (AIOD) announced this month its launch of the Purus Assurance System, a fluid analysis program administered by POLARIS Laboratories™ to support AIOD's newest brand, Purus.
Training
Salt Lake City
Cooling Systems Maintenance
September 20, 2010Salt Lake City
Practicing Oil Analysis
September 21-22, 2010Edmonton, AB
Cooling Systems Maintenance
October 26, 2010
Tradeshows & Conferences
Oil Sands Show
Ft. McMurry, Alberta
September 15-17, 2010Lloydminster Heavy Oil Show
Lloydminster, SK
September 15-16, 2010
