Please Note: You are viewing the unstyled version of POLARIS Laboratories. Either your browser does not support CSS (Cascading Style Sheets) or it is disabled. As a result, much of this website will not look the way it was intended, although all of its contents will be accessible to you. For more information, visit our Browser Support page.

Skip to Primary Site Navigation, Secondary Site Navigation, Content, Company Address


Oxidation

Definition:

Oxidation measures the breakdown of a lubricant due to age and operating conditions. It prevents additives from performing properly, promotes the formation of acids and increases viscosity.

Standard Test Method Used:

FTIR - ASTM E2412

Reporting Measurement:

abs/cm (absorbance units per centimeter)

Amount of Sample Needed:

40 mL

Test Limitation:

Significant contamination of water, glycol, soot or fuel may affect all FTIR results. Ester-based lubricants will show high oxidation values.

FTIR illustration

(click on image for larger version)


Top

News

POLARIS Laboratories™ to provide fluid analysis for AES Defence Early Failure Detection Centre

POLARIS Laboratories™, an innovative leader in fluid analysis services in North America, announced today their partnership with UK-based AES Defence who provides oil analysis services for more than 1,500 British military vehicles.

Read More

Sign Up for eNewsletters


Training

  • Salt Lake City
    Practicing Oil Analysis
    March 30-31, 2010

  • Houston
    Practicing Oil Analysis
    June 22-23, 2010

  • Indianapolis
    Cooling Systems Maintenance
    July 20, 2010

View complete schedule and registration information


Tradeshows & Conferences

  • Truck World
    Toronto, ON
    April 15-17, 2010

  • CIM
    Vancouver, Canada
    May 9-12, 2010

View all tradeshows