Primary Navigation
RPVOT
Definition:
RPVOT (Rotary Pressure Vessel Oxidation Test) measures the oxidation stability of a turbine oil. The sample is placed in a vessel that contains a polished copper coil. The vessel is then charged with oxygen then placed in a bath at a constant temperature of 150°C. Oxidation stability is expressed in terms of the time required to achieve a 25.4 psig pressure drop from maximum pressure.
Standard Test Method Used:
Reporting Measurement:
Minutes
Amount of Sample Needed:
200 mL
Test Limitation:
Test is primarily used for turbine and compressor oils.
Quick Links
News
New Fuel Test Packages Will Reduce Fleet Expenses and Downtime
POLARIS has developed an extensive range of fuel troubleshooting test packages that can confirm the quality of bulk deliveries and resolve what might be causing costly repairs and fleet downtime. Fleet managers spend more money on fuel than any other operating expense, so this is an area of great importance.